Chapter 3: Installing the system
18
Mounting the SAILOR 3027
•
Power source available.
The power source must be placed as close as possible to the terminal.
•
Grounding available.
Make sure that the shield of the CAN cable is connected to a proper
ground, i.e. the ship’s structure/hull. This is very important in order to
protect persons and equipment from lightning and safely bypass
interference from Radar, VHF/MF/HF radio equipment and other
environmental sources of interference.
Important
Do
not
make the ground connection at the SAILOR 3027
end of the CAN cable. Instead, connect the shield of the
CAN cable to the
symbol in the 15 V DC output (X2) on
the SAILOR 6081.