Chapter 5: Installation check and test
Testing the system
53
555
In
st
a
ll
a
ti
on c
h
ec
k and
te
st
5.2.3 Testing the SAILOR 6101/6103 Alarm Panel
When the system is connected and started up, check that the Alarm Panel
display shows all connected units.
•
SAILOR 6101 may show Inm-C 1 and/or Inm-C 2
•
SAILOR 6103 may show Inm-C 1, Inm-C 2, VHF 1, VHF 2, MF/HF 1 and/or
MF/HF 2
To test the light and sound indicators in the Alarm Panel, do as follows:
1. Press and hold the
Test
button on the Alarm Panel.
Verify that all light indicators and alarm buttons are flashing.
2. While holding the
Test
button, press any other button on the Alarm Panel,
including the
Distress
button.
The buzzer sounds to indicate that the pressed button and the buzzer are
working.
5.2.4 Backup supply test
With the system connected and switched on, switch off or remove the AC input
to the SAILOR 6081 PSU and Charger. The system should continue to work
uninterrupted from the 24 V DC backup battery.
You can check the status of the backup battery in the bottom left corner on the
SAILOR 6006.
For detailed Power status, Select
System > Power
.
Note
This test only verifies the function of the Alarm Panel itself, not of
any connected equipment nor the total system.
Summary of Contents for SAILOR 6110
Page 1: ...INSTALLATION MANUAL SAILOR 6110 GMDSS System...
Page 2: ......
Page 36: ...Chapter 3 Installing the system 26 Mounting the SAILOR 1252 printer...
Page 66: ...Chapter 5 Installation check and test 56 Generating a diagnostic report...
Page 78: ...Glossary 68...
Page 81: ......
Page 82: ...98 130752 A Thrane Thrane A S info thrane com www thrane com...