11
Direct Venting
The OD6 may also be horizontally vented through a side wall. Direct venting is
only allowed when using the approved Direct Vent Termination kit and Direct
Vent Accessory kit listed in the table below, and is limited to a maximum length
of 15’.
Table 2: Side wall vent kits
The Direct Vent Termination kit consists of a concentric through-the-wall vent
termination/inlet air vent hood and 15’ of Stainless Steel Insulated Flexible Pipe
that requires 2” clearance to combustibles.
A field supplied smooth wall 4” combustion air pipe will need to be provide to
connect the combustion air from the termination hood to the burner. The direct
vent accessory kit will provide the fittings needed to connect the 4” pipe to the
burner. The combustion air inlet can be installed through the either the lower left
or right side casing knock-out.
For proper installation follow the Instruction provide with the Direct Vent
Termination Kit.
Power (Side-Wall) Venting – Important Note Regarding
c
CAUTION: Thermo Products, LLC will NOT assume responsibility for
damage to, and deterioration of, exterior building materials, e.g. brick,
siding, clapboards, and etc., in close proximity to the vent terminal due to
operation of a power vented, oil furnace. This policy is applicable
regardless of the cause of sooting.
NOTICE: Thermo Products recommends the use of a chimney to vent
residential oil furnaces. If a power venter must be used, it is the
responsibility of the installer and power venter manufacturer to design,
assemble, and demonstrate proper operation of the power venting system
with the furnace.
SIDE WALL VENTING APPLICATION ORDER INFORMATION
BURNER
VENT TERMINATION KIT
(15’ application MAX)
PART NUMBER
SIDE WALL VENT
ACCESSORIES KIT
PART NUMBER
Beckett AFG
AOPS8393
AOPS8394
Riello BF3
AOPS8393
AOPS8395
Carlin EZ-1HP
AOPS8393
AOPS8432
Summary of Contents for OD6FA072D48
Page 32: ...31 APPENDIX B ELECTRICAL DIAGRAMS OD6 FAO72D48 NRGMAX CONTROL...
Page 33: ...32 OD6 FAO72DV5 NRGMAX CONTROL...
Page 34: ...33 OD6 FAO72D48 UT CONTROL...
Page 35: ...34 OD6 FAO72DV5 UT CONTROL...
Page 37: ...36 APPENDIX D REPLACEMENT PARTS OD6FA072D48 OD6FA072DV4...
Page 38: ...37...
Page 39: ...38 OD6RA072D48 OD6RA072DV4...
Page 40: ...39...
Page 41: ...40...
Page 42: ...41...
Page 43: ...42...