Electrical Maintenance (Rev. 04/03)
61
Run Capacitors
Voltage Test (This test is valid only if the motor is running at
normal speed and the motor start contactor is de-energized.)
Check the voltage between T3A and T3E and between T3B and
T3F at the test point strip. The voltages should be within 10% of
the sum of the line voltage and the secondary transformer
voltage. If the voltage is low, the run capacitor in that circuit is
defective. / Replace as necessary.
Current Test (This test is valid only if the motor is running at
normal speed and the motor start contactor is de-energized.)
NOTE: Only one of the two T3E and one of the two T3F
wires connected to the motor will carry a current while
running.
Check the current in T3E and T3F at the motor with an inductive
ammeter. Both currents should be 4 to 8 amps. If a current is
below 4 amps, the run capacitor in that circuit is defective. /
Replace as necessary.
PROBLEM/PROBABLE CAUSE
TEST/SOLUTION
Summary of Contents for KD-II SR
Page 4: ......
Page 8: ......
Page 13: ...Safety Precautions Rev 04 03 v AEA40...
Page 14: ...Safety Precautions Rev 04 03 vi AEA38...
Page 33: ...Unit Description Rev 04 03 19 1 Evaporator 2 Access Door Rear View Curbside KD II SR 1 2 AEA38...
Page 37: ...Unit Description Rev 04 03 23 Power Receptacle Box KD II SR 50 AEA42...
Page 58: ...Remote Control Panel Features Rev 04 03 44...
Page 112: ...Refrigeration Maintenance Rev 04 03 98...
Page 120: ...106...
Page 146: ...132...
Page 156: ...142...
Page 162: ...148...
Page 170: ...156...
Page 172: ...158...
Page 173: ...159 KD II 30 Schematic Diagram Page 1 of 2...
Page 174: ...160 KD II 30 Schematic Diagram Page 2 of 2...
Page 175: ...161 KD II 30 Wiring Diagram Page 1 of 2...
Page 176: ...162 KD II 30 Wiring Diagram Page 2 of 2...
Page 177: ...163 KD II 50 Schematic Diagram Page 1 of 2...
Page 178: ...164 KD II 50 Schematic Diagram Page 2 of 2...
Page 179: ...165 KD II 50 Wiring Diagram Page 1 of 2...
Page 180: ...166 KD II 50 Wiring Diagram Page 2 of 2...
Page 181: ...167 KD II 50 SR 230 1 60 Wiring Diagram Page 1 of 2...
Page 182: ...168 KD II 50 SR 230 1 60 Wiring Diagram Page 2 of 2...