Remote Control Panel Features (Rev. 04/03)
42
µP-T UNIT SELF CHECK TEST
The Unit Self Check is a functional test of the unit’s operat-
ing capability. Once the test is started by the operator, it is
fully automatic and requires no operator attendance.
Starting the Unit Self Check
The following steps are necessary to start a Unit Self Check:
•
Disconnect the power cord, if present.
•
Turn the On-Off switch ON.
•
Clear any alarms.
•
Press and hold the TK Logo key for at least 3 seconds
until the Unit Self Check [USC] prompt screen appears.
•
Press the Enter key. The display will briefly show
[Lod] and the unit will then start the Unit Self Check.
If any alarms were not cleared before starting the Unit Self
Check, they will be displayed at this time. They can be
cleared by pressing the Enter key.
The balance of the Unit Self Check is fully automatic and
requires no operator attendance. The following tests are per-
formed:
Preheat and Start
The controller will automatically preheat and start the diesel
engine.
Display Check
All segments of the display will be lighted at the same time.
X
74
Microprocessor Reverted to Default Settings
X
77
Internal Fault Code, Factory or Dealer Reset
ALARM CODE DEFINITIONS
Always record any alarm codes shown.
Alarm codes preceded by a dash (-) were detected during a Unit Self Check
Stored
Check
Shutdown
Code
Description
Show Programmable Settings
All programmable settings will be sequentially displayed.
These settings may be verified by the operator if necessary.
Defrost Check
The operation of the damper door is checked.
RPM Check
The diesel engine RPM is checked in both high and low
speed.
Cooling Check
The ability of the unit to cool is checked.
Heating Check
The ability of the unit to heat is checked.
Cooling Check
A second cooling test is performed to ensure the unit can
switch from cool to heat and back to cool.
Unit Self Check Report
At the completion of the Unit Self Check, the check results
will appear on the display. They will remain until any key
on the controller is pressed. Check results are shown as
either [PASS], [CHEC] or [FAIL].
[PASS] — The unit has passed the Unit Self Check.
Summary of Contents for KD-II SR
Page 4: ......
Page 8: ......
Page 13: ...Safety Precautions Rev 04 03 v AEA40...
Page 14: ...Safety Precautions Rev 04 03 vi AEA38...
Page 33: ...Unit Description Rev 04 03 19 1 Evaporator 2 Access Door Rear View Curbside KD II SR 1 2 AEA38...
Page 37: ...Unit Description Rev 04 03 23 Power Receptacle Box KD II SR 50 AEA42...
Page 58: ...Remote Control Panel Features Rev 04 03 44...
Page 112: ...Refrigeration Maintenance Rev 04 03 98...
Page 120: ...106...
Page 146: ...132...
Page 156: ...142...
Page 162: ...148...
Page 170: ...156...
Page 172: ...158...
Page 173: ...159 KD II 30 Schematic Diagram Page 1 of 2...
Page 174: ...160 KD II 30 Schematic Diagram Page 2 of 2...
Page 175: ...161 KD II 30 Wiring Diagram Page 1 of 2...
Page 176: ...162 KD II 30 Wiring Diagram Page 2 of 2...
Page 177: ...163 KD II 50 Schematic Diagram Page 1 of 2...
Page 178: ...164 KD II 50 Schematic Diagram Page 2 of 2...
Page 179: ...165 KD II 50 Wiring Diagram Page 1 of 2...
Page 180: ...166 KD II 50 Wiring Diagram Page 2 of 2...
Page 181: ...167 KD II 50 SR 230 1 60 Wiring Diagram Page 1 of 2...
Page 182: ...168 KD II 50 SR 230 1 60 Wiring Diagram Page 2 of 2...