56
Charging the Circuit
1. Connect the gauge manifold to the suction and discharge line intakes of
the condenser unit.
2. Connect the refrigerant bottle to the gauge manifold and place it on a
set of scales.
3. Open the refrigerant bottle valve and
drain the gauge fitting line
.
4. Keep the low pressure side valve of the gauge manifold closed. Open
the high pressure side valve.
5. Add refrigerant until reaching approximately
0.95 kg/2.1 lb of R-134a.
6. Close the refrigerant bottle valve and the high side valve of the gauge
manifold.
7. Start the vehicle engine running at around 1000 rpm and switch on the
unit.
8. Set the unit thermostat at 0ºC/32ºF (see operating manual).
9. Run the unit until it reaches a temperature close to that indicated, and a
high circuit pressure of 12.5 bar / 180 psig for R-134a
. Partially
close the air intake to the condenser if necessary.
10. Open the low side valve of the gauge manifold and the refrigerant
bottle valve, and add refrigerant slowly until no bubbles can be seen
through the liquid sight glass.
11. Close the refrigerant bottle and gauge manifold valves.
12. Leave the unit running for 15 minutes.
13. Only if you are installing a unit without electrical standby, turn off the
unit, stop the vehicle and remove the gauge manifold.
Summary of Contents for B-100-10
Page 9: ...9 Required Tools...
Page 13: ...13 Installing the Condenser Unit roof mounted ASA052 T 10 min...
Page 15: ...15 Installing the Condenser Unit roof mounted T 12 min...
Page 17: ...17 Installing the Condenser Unit front mounted T 10 min...
Page 19: ...19 Installing the Condenser Unit front mounted C T 15 min...
Page 21: ...21 Installing the ES100 Evaporator Unit T 20 min...
Page 23: ...23 Preparing Refrigeration Hoses T 10 min...
Page 25: ...25 Connecting Hoses to the Condenser Unit T 10 min...
Page 27: ...27 Connecting Hoses to the ES100 Evaporator T 14 min...
Page 29: ...29 Electrical Connections in the ES100 Evaporator T 10 min...
Page 31: ...31 Drain Circuit in the ES100 Evaporator T 5 min...
Page 33: ...33 Circuit Seal Test...
Page 35: ...35 In Case of Leaks 250 psig...
Page 37: ...37 Installing the In Cab Control 1 3 T 10 min...
Page 39: ...39 Optional Internal DIN Adaptor T 5 min...
Page 41: ...41 Control Cable Connection T 5 min...
Page 43: ...43 Battery Connection T 15 min...
Page 45: ...45 Fitting the Power Supply Units with Electric Standby T 10 min...
Page 47: ...47 Door Switch Connection DSW1 CHW T 1 min...
Page 49: ...49 Installing the Deflector T 5 min...
Page 51: ...51 Installing the Hose Covers T 12 min...
Page 57: ...57 Charging the Circuit...
Page 58: ...58 Outline Drawings...
Page 59: ...59 Outline Drawings...
Page 60: ...60 Outline Drawings...
Page 61: ...61...
Page 62: ...62...
Page 63: ...63...
Page 64: ...64...