Stage 1
SCR
TITRE:
Diagramme électrique
VOLTMAX: 23 @ 75kW
208-240V/3ph
NOM DE FICHIER:
VOLTMAX
PAGE
1 de 1
DATE IMPRESSION:
No DESSIN:
THERMO 2000 inc.
500, 9e avenue
Richmond (Québec)
J0B 2H0
REV.
DESCRIPTION
DATE
Par/Verif
SCR
24
Com
24
VAC
-
+
T1
L1
T2
L2
R2/B
R-4/B
L1
L2
L3
TX-1
208/240
x120V
Alimentation 120V Supply
voir détails de contrôle/See control details
CA
CB
CD
CE
Circuit 208V ou/or 240V x 3 ph Circuit
Basse tension 120VAC Low voltage
L1
N
120VAC
de TX-1
LWCO
HL-MR
HL-AR
CR1
SCR
CA
CB
CC
CD
R-2A
R-4/A
G
DO2-1
R-2
R-5/B
R-5/A
DO3-1
R-3
DO4-1
R-4
DO1-1
R-5
CE
TDR
TDR
LWCO
24Vac
Extension
R14
Extension
R14
Extension
R14
Extension
R14
SCR
TX-2
120:24
Controler
TM171
LWCO :
Bas niveau d’eau
/ Low water cut off
HL-MR: Haute limite manuel reset / High limit manual reset
HL-AR: Haute limite reset auto./ High limit automatic reset
SCR: Relais de modulation / Modulating relay
C : Contacteur principal /Main contactor
R: Relais de puissance / Power relay
Sectionneur /
disconnect
OPTION
R-3/B
R-3/A
Stage 2
Stage 3
EL#3
EL#2
EL#4
EL#5
CC
Fusible
(Voir note 1)
Remplacable par
un relais
standard 2 poles
Note 1:
En Option sur les modèles dont l’ampérage max
. est
inférieure à 120A. / In option on models on models having an
amperage of 120A and less.
Press.
T in
T out
RD
VT
GN
CR1- 2
HL&LWCO
W2/DHW
W1
120Vac
R2
stg-2
R3
stg-3
R4
stg-4
R5
stg-5
ALARM
POMPE
CHAUFF.
W1
POMPE
W2/
DHW
SCR
OCC.
(On 5 stg models)
Note 2
COM.
Filage en usine
Factory wiring
Filage au chantier
Field wiring
CR-1
SR-1
0-10Vdc
AUX.
AUX.
24Vac+
24Vac-
Outdoor
T sensor
BACnet
MSTP
120 ohm
24Vac +
+
Sens. Ext.
RS485
Note2
Note
2
24Vac-
24Vac
24Vac+
TM171PFE03
TM171EP14R
TM171EP14R
G
DI4 DI3 DI2 DI1 AO2 AO1 G 24v+ 5v+ AI4 AI3 AI2 AI1 G
24VAC
DO1
DO2
DO3
DO4
N
DIP
SWITCH
CAN
24V:50mA
5V: 20mA
DO1
DO2
DO3
DO4
N
G
DI4 DI3 DI2 DI1 AO2 AO1 G 24v+ 5v+ AI4 AI3 AI2 AI1 G
24VAC
24V:50mA
5V: 20mA
DIP
SWITCH
CAN
1
2
3
4
5
6
7
L
H GS
1 2
3 4
1
2
3
4
5
6
7
L
H GS
1 2
3 4
CAN
L H GS
G AI3 AI2
ETHERNET
GS
24Vac
BU
GN
GN
BK
BU
GY
TN
B
K
WH
RD
BK
VT
BK
RD
VT
BN
BK
RD
WH
TN
B
U
RD
BN
GY
Y
E
RD
G
Y
CT
GY
VT
Y
E
OG
YE
OG
24Vac+
GN
VT
GN
TN
RMSP
0-10Vdc
Cap. T
G
OG
B
K
Y
E
BN
OG
YE
Bornes de raccordement de contrôles bas voltage
Low voltage Control terminal strip
BU
BU
-
-
BK
BK
Note 2: Ce contact est utilisé pour contrôler une chaudière
auxiliaire sur les modèles ayant 4 stages et moins / This contact
isused to control an auxiliary boiler on models having 4stages
and less
.
4 stg models
5 stg models
4 stg models
5 stg models
4 &5 stg models