INSTALLATION
8
2.4 SHIELDING GAS CONNECTIONS
The gas valve (PROCESS SELECTOR switch in HF or LIFT TIG
MODE) will not work unless the OUTPUT CONTACTOR switch
is in the REMOTE position and a remote control device is con-
nected to the REMOTE 14 receptacle.
The gas input and gas output fittings have 5/8-18 right-hand
threads. To make gas connections, proceed as follows:
1. Route and connect a hose of suitable length and construction
from the shielding gas supply to the GAS INPUT fitting on
rear of unit.
2. Connect the torch gas hose to the GAS OUTPUT fitting on
front of unit.
The gas flow must be accurately controlled with a regulator and
flowmeter. Recommendations for rate of gas flow should be
obtained from the torch manufacturer.
It is recommended to use a nylon or synflex type hose to supply
the shielding gas to the unit. The use of rubber can result in
potential contamination of welding gas.
NOTE
NOTE
GAS INPUT
A-00069
GAS OUTPUT
A-00068