7
INSTALLATION
2.3 WELD OUTPUT CONNECTIONS (continued)
Figure 2-B
Weld Output Connections - Lower Front Panel
Refer to Figure 2-B and:
a. Connect torch cable to the negative (-) weld output receptacle
as follows: align keyway, insert plug, and rotate plug clock-
wise until it is securely seated in receptacle.
b. Connect work cable connector to the positive (+) weld output
receptacle as follows: align keyway, insert plug, and rotate
plug clockwise until it is securely seated in receptacle.
Do not connect torch cable to positive output post on power
supply when Gas Tungsten Arc Welding in the AC mode.
a. Connect end of electrode holder cable to the positive (+) weld
output receptacle as follows: align keyway, insert plug, and
rotate plug clockwise until it is securely seated in receptacle.
b. Connect work cable connector to the negative (-) weld output
receptacle as follows: align keyway, insert plug, and rotate
plug clockwise until it is securely seated in receptacle.
For AC or DCEN (Electrode Negative/Straight Polarity) reverse
cable connections to weld output receptacles; electrode becomes
negative.
Gas Tungsten
Arc Welding
(DCEN) and (AC)
(Electrode Negative/
Straight Polarity or AC
Alternating Current)
NOTE
Shielded Metal
Arc Welding
(DCEP)
(Electrode Positive/
Reverse Polarity)
NOTE
WORK
ELECTRODE
A-00067
DC
AC
Summary of Contents for 400 GTSW AC/DC