48
Temperature control of the
CUBE
LT
use a temperature sensor located in the
RC4LT
housing. As the temperature is taken from the ceiling and close to the radiator, it is nor-
mal to see a difference between this measurement and a measurement taken elsewhere
in the wine cellar.
Depending on the level of insulation of the wine cellar as well as its geometry, this differ-
ence could play between a few hundredths of a degree up to a few degrees.
If this difference is significant, it may be necessary to “cheat” the temperature demand
to obtain the desired value. That is to say, if it is noted for example that the temperature
in the cellar is 16°C whereas 14°C is requested, it will then be necessary to give the sys-
tem a setpoint of 12°C in order to obtain in the wine cellar the desired 14°C.
It is important to let the system run for at least three days before starting this type of
adjustment. The room and the bottles must cool completely before you see the actual
behavior of the wine cellar.
A temperature diference between my thermometer in the wine cellar and the system display.