Failure Without System Error Code
1. Check the system screen to see if an error code appears.
2. Check if the water chiller is turned on and functional. By default the chiller should
work to maintain the water temperature at 8°C [46°F].
3. Check if the water is circulating well in the system. By touching the connections at
different places on the loop, the components should be at roughly the same tempera-
ture. If not, look for a pinched hose that would prevent water flow.
4. Stop and restart the control box a few times to try to get rid of any air bubbles that
may have formed in the water cooler pump or tank.
5. Contact your The Wine Square product retailer.
he high temperature in the wine cellar, no cold air comes out of the
RC4LT
unit.
1. Check that the construction of the wine cellar meets the minimum system require-
ments.
2. Check if the humidity in the house is normal. Very often too high humidity in the
wine cellar is a sign of poor humidity management in the house. Studies show that
to maintain good air quality in a home, humidity should be between 30% and 50% at
21°C.
3. Lower the water chiller setpoint to cause more condensation in the wine cellar and
thus drier the air.
• To change the water temperature, on the chiller control:
a) Press the SET key for 3 seconds to view the selected value and the unit of
measurement icon (C or F) starts flashing.
b) Modify the value using the keys marked with an arrow.
c) Press the SET key to confirm the value.
4. Contact your The Wine Square product dealer.
Humidity too high (> 80%) in the wine cellar.