37
Water Replacement
Every 5 years, the water in the system must be replaced. To do this, the system must be
completely drained and refilled.
1. Unplug the Water Chiller and the
CUBE
LT
2. Position a container under the control box
3. Open the front of the control box using a coin
4. Disconnect the water supply tube from the
control box (A), the left tube
5. Put the section of the tube coming from the
wine cellar in the bucket
6. Using a compressor limited to 15psig, inject
air into the tubing connected to the control
box.
7. Inject air until water stops coming out
8. Clean the water filter in position (A)
9. Replace the water filter
10. Reconnect the tube coming from the cellar to
the control box
11. Refill the system as outlined in the system
start-up procedure.
A
NOTE :
To open the water filter, take
the filter by the two metal sections
and unscrew to release the central
part.
Summary of Contents for CUBE LT
Page 1: ...CUBELT User Manual...
Page 2: ...DESIGNED AND MADE IN CANADA...
Page 52: ...50 APPENDICES...
Page 55: ...53 PARTS LIST...
Page 58: ...56 NOTES...
Page 60: ...WWW THEWINESQUARE COM The Wine Square 2022 All rights reserved R0 0...