12
A
Position RC4LT in the wine cellar. It is important to consider the thickness of the insula-
tion, finishing material and glass envelope when locating the final location of the unit.
Check that the clearance necessary for the correct operation of the unit is respected.
B
Minimum Clearance
Front (A)
____________________________
Side (B)
_________________________________
Back (C)
_____________________________
1.75’’
1”
1’’
A
C
Front
Back
Install a wood blocking at least the size of the unit and at least 5/8’’ thick at the loca-
tion of the unit. Provide an opening of maximum 2’’x 10’’ tangent with the middle of the
location of the unit, for the passage of the tubes. Generally two holes of 1-3/4 ‘’ and one
of 0.75 ‘’ are sufficient.
28.5”
[ 724 ]
10
.25”
[ 260
]
Install 2 x 1/2” insulated PEX pipes between the location of the control box (usually locat-
ed in the garage or mechanical room) and the outlet of the RC4LT unit (opening made
in the wood blocking installed previously) .
Put “duct tape” type adhesive tape between the different sections of insulation (joint)
covering the tubes.
B
NOTE :
It is preferable to use PEX tube supports rather
than elbows when a 90° is required.