4-2
.
Rear panel
20. MASTER/SLAVE connection terminals
These terminals are used for one-control parallel operation in the
master/slave mode. (For details, see section 5-11 "One-Control
Parallel Operation" below.)
21. Rear panel remote control terminals
These terminals are used for constant-voltage, constant-current
and output on/off remote controls. (For details, see section 5
"OPERATION PROCEDURES" below.)
22. Status signal output terminals
These terminals output the CV, CC and ALARM status signals.
(For details, see section 5-8 "Status Signals" below.)
23. Voltage and current monitor signal output terminals
These terminals output the monitored voltage and current of the
PA-B series in voltages. (For details, see section 5-9 "Monitoring
Voltage and Current" below.)
24. AC inlet
The AC inlet connector of the PA-B series.
25. Input AC voltage selector switches
The 2 combination switches are located in the rear panel of
the unit to select the input AC voltage. Set them as shown
b
elow to select AC 100V, 110V, 200V or 220V. However, it
becomes a switch of AC100V, 115V, 200V, and 230V
according to the model. Which voltage can be set is
displayed in rear panel of the PA-B SERIES. (Please refer to
the table for the A.
Voltage setting table)
Use 115V for actual 120V AC operation.