3. Usage of connection terminals on rear panel
Follow the procedures shown below to connect the cables to the
terminals on the right of the rear panel.
1) Apply a flathead screwdriver (thin screwdriver) to the slit on the
right of the round (or square) hole for connecting a cable.
Press it and insert the cable conductor into the round (or
square) hole.
2) Disconnect the cable in the same manner. Press the slit with
the screwdriver and pull out the cable.
NOTE: Applicable wires
:
Solid wire: 0.4 to 1.0 mm dia. (AWG26 to 18)
Braided wire: 0.3 to 0.75 mm²
(AWG22 to 20)
Element wire: 0.18 mm dia. or more
Standard peel-off length: 10 mm (Solder the peeled conductors
of a braided wire.)
4. GP-IB control
*
It is possible to set the constant-voltage and constant-current
values and control the OUTPUT switch of the PA-B series from
a computer through the GP-IB bus (in conformity to
IEEE-488-1978) if the optional GP-IB adapter GP-600B is used.
*
A single GP-600B may control the following of each PA-B unit.
- Output voltage and current setting
- OUTPUT ON/OFF
- ALARM detection
- CV
CC, CC
CV mode interrupt
1) Press with the screwdriver.
2) Insert the cable