6
Item
PA10-5B
PA18-1.2B
PA18-2B
PA18-3B
PA18-5B
PA36-1.2B
PA36-2B
PA36-3B
FUNCTIONS
OVP
ALARM LED goes on
Approx. 5 to 105%
OHP
ALARM LED goes on
Output goes off when internal heat sink temperature reaches 105 ±5°C.
(Only PA18-5B,PA36-3B are 110°C)
Output switch
Remote on/off control
Output may be turned on or off with remote control switch on rear panel.
(Front/rear control is selected with switch on front panel.)
V/I check switch
Indicator indicates constant-voltage or constant-current set value when switch is turned on.
Remote sensing
Enabled with (+S) and (-S) terminals on front panel. May correct up to 0.5 V, one way.
*5
Voltage monitor
Output voltage to monitor
voltage ratio
Output voltage 0 to rated voltage/approx. 0 to 10 V output (Connector on rear panel)
Current monitor
Output current to monitor
voltage ratio
Output current 0 to rated current/approx. 0 to 10 V output (Connector on rear panel)
Status signal
CV
Open collector output, Low in CV mode
CC
Open collector output, Low in CC mode
ALARM
Open collector output, Low in alarm mode
Parallel operation
Master/slave system
Capable of one-control parallel operation.
(Current error: ±20%, up to 3 units. One-control is applicable to same models only.)