9
Item
PA80-1B
PA120-0.6B PA160-0.4B PA250-0.25B PA250-0.42B PA350-0.2B PA600-0.1B
OPERATING CONDITIONS
Operating temperature/humidity range
0 to 40°C 10% to 80%RH
Storage temperature/humidity range
-20 to 60°C 10% to 85%RH
Cooling method
Natural convection
Output polarity
Positive or negative grounding possible
Ground proof voltage
±250VDC
±500VDC
±600VDC
Between the chassis and
input power supply terminal
DC500V 30MΩor more
Insulation
resistance
Between the chassis and
Output terminal
DC500V 20MΩor more
DC600V
20MΩ
or more
Insulated
resisting pressure
Between the chassis and
input power supply terminal
AC1.5kV /1 minute
POWER REQUIREMENTS
Input Voltage, frequency
AC220V±10%
、
50/60Hz
、
1
φ
Power consumption
(
VA
)
At the time of AC rated input
Approx.
170VA
Approx.
155VA
Approx.
150VA
Approx.
140VA
Approx.
220VA
Approx.
150VA
Approx.
130VA
Power consumption
(
W
)
At the time of AC rated input
Approx.
140W
Approx.
115W
Approx.
100W
Approx.
105W
Approx.
150W
Approx.
110W
Approx.
100W
DIMENTIONS AND WEIGHT
Dimensions(mm)
104
×
124
×
350
Max. dimensions(mm)
106.2
×
144.3
×
368.3
Weight
Approx.
6.6kg
Approx.
6.6kg
Approx.
6.6kg
Approx.
6.6kg
Approx.
6.6kg
Approx.
6.6kg
Approx.
6.6kg
ACCESSORIES
One instruction manual,
One adjustment driver,
One power cable
(
3P
)
*1: By LCL (internal sensing) at the sensing terminal.
*2: Measurement is done by ground either positive or negative output.
*3:
Responding time when output voltage returns to within 0.05%+10mV of the rating at ON.
*4: After worm up for approximately 30 minutes when the current is fed.
*5: When the power supply output is rated value or less.