18
15. Remote sensing (PA10-5B, PA18-1.2B, PA18-2B, PA18-3B,
PA18-5B, PA36-1.2B, PA36-2B and PA36-3B)
・
REM/LCL selector switch
This switch is normally set to the LCL (internal sensing) position.
Set it to the REM position to execute remote sensing.
NOTE: Do not set this switch to the REM position unless the
remote sensing function is used. Connect the sensing
cable and load cable firmly to prevent them from being
disconnected during sensing.
・
+S terminal
The (+) output remote sensing terminal.
・
-S terminal
The (-) output remote sensing terminal.
16. OVP control
This control is used to set the operating voltage of the OVP
(over-voltage protection) circuit.
17. MASTER/SLAVE selector switch
This selector switch is used to carry out one-control parallel
operation in the master/slave mode. Set it to the MASTER
position normally. (For details, see section 5-11 "One-Control
Parallel Operation" below.)
18. Rear panel control selector switch
This switch selects the constant-voltage, constant-current and
output on/off remote controls. Set it to the OFF position
normally. Operations on the front panel are enabled at this
position. Remote controls are enabled at other positions.
(For details, see section 5 "OPERATION PROCEDURES" below.)
19. Rear panel control volume
This volume is used for remote constant-voltage and constant-
current controls.
(For details, see section 5 "OPERATION PROCEDURES" below.)