38
5-12
.
Recharging Battery
*
A capacitor of several µ to dozens of µ is connected to the output
of the PA-B series. The PA-B series incorporates a circuit for
discharging electric charges from the capacitor when power is
turned off. Be sure to connect a diode for preventing current
discharging as shown above when using the PA-B series for
recharging a battery.
NOTE: Use a diode having enough capacity to withstand the rated
current of the PA-B series.
*
Be sure to connect a relay between the +S and -S wires in series
as shown above when recharging a battery using the voltage
remote sensing function. The relay must close when the output
is turned on and open when the output is turned off. Discharged
current also flows through the +S and -S wires.
Diode for preventing current discharging
-
+
Battery
+
-
G
+
-
Battery
Closes when output is turned on.
+
-
G