Premier 24
Installation Manual
Installation
INS248
27
Connecting a Computer
The
Premier 24
supports local uploading and downloading
between the control panel and a PC running
Wintex UDL
software. Uploading and Downloading can be used to
program and interrogate the control panel.
In order for the computer to work correctly, ensure that it is
set to the following:
•
UDL Password (see page 66 for details)
!
In order to upload and download to the control
panel locally, a
PC-Com
lead is required.
PC-Com
Aux 12V
+
B
a
tt -
A.
C
.
Battery
Network
Bell
F5
F2
F3
F4
Engineer
Remote
C om2
J P6
Com1
Load De f aul ts
Tx2 Rx 2
Tamp
Strb 0V
Bell+12V
P g 1
A u x
1 2 V
S p k -
+
-
A u x Ta m p
Connecting a Printer
The
Premier 24
supports printer facilities. The printer is
connected to the Com 1 connector located on the control
panel and can be used to print the control panel event log.
In order for the printer to work correctly, ensure that it is
set to the following:
•
Baud Rate = 4800
•
Parity =
None
•
Start Bits = 1
•
Stop Bits = 2
•
Data Bits = 8
•
DTR =
Normal
•
Columns = 40 or 80 (see page 44)
!
In order to connect a printer to the control panel, a
PRINT-Com
lead is also required.
DATAC or RS232 printer
RS232 Data
Connect to
COM1
PC-Com