Installation
Premier 24
Installation Manual
18
INS248
8XP
Zone Expander
The
Premier 8XP
Zone Expander has:
•
8 fully programmable zones
•
8 fully programmable –ve applied outputs
•
1 programmable auxiliary input
•
A fully adjustable speaker output
Expander Layout
Zones
5 & 6
Power LED
Tamper
Switch
Engineers
Keypad
Interface
Network
Terminals
Aux
12V
Aux
12V
Zones
7 & 8
Zones
1 & 2
Zones
3 & 4
Outputs
1 to 8
Speaker
Output
Aux
Input
Com Port
1
2
3
OUTPUTS
4
5
6
7
8
Zone 6
Zone 5
Aux 12v
-
Zone 8
Zone 7
T
A
T
A
T
A
T
A
NETWORK IN
+ -
T
R
+ -
T
R
NETWORK OUT
Remote
Power
Zone
2
Zone
1
T
A
Aux 12v
-
+
Zone 4
Zone 3
T
AT
AT
A
Aux
Input
-
Spk
-
+
1
ON
2 3 4
PSU
D
S
YPE0123456
Tamper
Disable
Address
Switch
Connecting Expanders
Expanders are connected to the network terminals located
at the bottom left hand corner of the control panel (see
pages 13 & 14 for connection details).
Expander Addressing
Each Expander must be assigned a different address using
the DIL switches located in the centre of the PCB. The table
below shows the expander addressing:
Address
DIL 1
DIL 2
DIL 3
DIL 4
1
On
or off
Off
Off
Off
2
4
3
1
2 Off
On
Off Off
2
4
3
1
!
Never set two expanders on the same network to the
same address.
Zone Numbering
The table below shows the zone allocation when the
expanders are installed:
Address
Zones
1 9
-
16
2 17
-
24
Expander Zones
The expander has eight programmable zones (see page 21
for wiring details). Each zone is also fully programmable
(see page 34 for programming details).
!
When using an
8XP
Zone Expander, the wiring
configuration must always be selected as ‘Double
EOL’ even if wired as Double Pole.
Expander Auxiliary Input
The expander has one programmable input. This auxiliary
input can be used to monitor auxiliary devices such as
tamper loops etc. Wire as per Aux Tamper shown on page 22
(see page 53 for programming details). The system will
respond as follows:
Input Status
System Response
0V Applied
Input Secure
0V Removed
Input Active
!
For further details on how the input status affects the
system please refer to page 53.
Expander Outputs
The zone expander has eight programmable outputs, which
can be used to drive auxiliary devices such as LED’s,
sounders or relays etc. Wire as per Panel Outputs shown on
page 24 (see page 53 for programming details). The
electrical characteristics for the outputs are shown below:
Outputs
Max Current
Type
1 to 8
100mA
Switched -ve
Expander Speaker Output
The expander has an output that can be used for driving up
to one 16
Ω
or two 8
Ω
loudspeakers (see page 22 for wiring
details).
Expander Com Port
The Com Port can be used to connect a
PSU200
montored
power supply or a
RadioPlus Inteligent Receiver
.
Expander Lid Tamper
The lid tamper of each expander can be disabled if required
by fitting a jumper link across the centre and right hand pins
of the ‘Enable Tamper’ pins (JP2) leaving the left hand pin
free. These pins are located to the left of the address DIL
switch just beneath the fuse.