Installation
Premier 24
Installation Manual
16
INS248
4XP
Zone Expander
Expander Layout
NETWORK IN
+ -
T
R
+ -
T
R
NETWORK OUT
JP1
Zone
2
Zone
1
T
A
Aux 12v
-
+
Zone 4
Zone 3
T
AT
AT
A
1
ON
2 3 4
O/P O/P
SPK+ SPK-
2-
1-
Engineers Keypad
JP4
D
S
JP2
Network IN
Terminals
Network OUT
Terminals
Outputs 1&2
Loud Speaker Terminals
Tamper Switch
Power LED
Address Switch
Zones
1 & 2
Zones
1 & 2
Aux 12V
Engineers Keypad
Interface
Com Port
Connecting Expanders
Expanders are connected to the network terminals located at
the bottom of the control panel (see pages 13 & 14 for
details).
Addressing
4XP expanders are addressed as one or (normally) two
keypads on the network. Each 4XP has to have a unique
address, which must not conflict with any keypad or any
other 4XP on the same network.
The following table shows the expander addresses & the
keypad slots that each would occupy.
Address DIL 1 DI L 2 DI L 3 D IL 4 Keypads
1
On
off off
off
1 & 2
2 off
On
off
off
2 & 3
3 off
off
On
off
3 & 4
4 off
off
off
On
4 (2 Zones)
Zones
The 4XP provides 4 alarm zones, 2 for each of the 2 keypad
slots it occupies. Each zone is fully programmable (see page
35) and has to be mapped to the system (see page 51).
Outputs
2 Programmable outputs are provided 1 for each of the 2
keypad slots occupied by the expander (see page 54 for
output programming)
Expander Speaker Output
One speaker output is provided for connecting one external
16
Ω
or 2 8
Ω
loudspeakers (see page 22 for details).
The speaker volume is programmed through the keypad setup
menu (see page 51)
!
The speaker is available on keypad 1 of the two
keypad slots the 4XP occupies. (ie if the 4XP address is
3, the speaker will programmed as belonging to
keypad 3).
Expander Com Port
The Com Port can be used to connect a
RadioPlus
Inteligent Receiver
.
iProx Module
iProx Layout
PIP0123456
Options
1
ON
2 3 4
1
ON
2 3 4
Address
RTE
N/C
N/O
Com
+
T
R
Spk
+
D0
D1
C1
L1-
C2
L2-
L+
Tamper
Ext
Coil
Remote
LED’
s
Relay
1
Ext
Int
Ext
Int
Internal Sounder
Off
On
Door Strike
Relay
Request to
Exit Input
Remote
Prox Coil
Connections
Speaker
Volume Adj
Network
Terminals
Wiegand
Interface
Connections
Speaker
Terminals
Option & Address Switches
Connection
The
iProx Module
is connected to the network terminals
located at the bottom of the control panel (see pages 13 &
14 for details).
Addressing
The
iProx Module
is addressed as a keypad and will occupy
a keypad slot on the network. The unit must have a unique
address, which must not conflict with keypad or any other
iProx Module
on the same network
The following table shows the addressing:
Address D IL 1 D IL 2 D IL 3 D IL 4
1
On
off off
off
2 off
On
off
off
3 off
off
On
off
4 off
off
off
On
Refer to the
iProx Module
manual for programming and
operating instructions.