Installation
Premier 24
Installation Manual
20
INS248
OP16
Output Expander
A maximum of 1 output module can be connected to the
network along with keypads and zone expanders.
The
Premier OP16
output module can be set up to mimic
the outputs of zone expanders.
!
In order for an output module to mimic zone
expander outputs, the output module must be
addressed the same as the zone expander that it is
mimicking.
Output Module Layout
Power LED
Tamper
Switch
Network
Terminals
Aux 12V
and Tamper
Output
NETWORK IN
+ -
T R
+ -
T R
NETWORK OUT
Power
1
A
m
p
A
ux
12v
1
Amp
2
4
3
1
BANK 1
Remote
Bank 2
Outputs
1 to 8
1
2
3
4
5
6
7
8
BANK 2
1
2
3
4
5
6
7
8
BANK 1
Bank 1
Outputs
1 to 8
Tmp
-
Aux 12V
+
+
-
2
4
3
1
BANK 2
Network
Terminals
Engineers
Keypad
Interface
Connecting Output Modules
Output modules are connected to the network terminals
located at the bottom left hand corner of the control panel
(see pages 13 & 14 for connection details).
Output Module Addressing
Each output module must be assigned a different address
using the DIL switches located in the centre of the PCB.
!
Bank 1 switch sets the address of the device that
Bank 1 outputs 1 to 8 will mimic.
!
Bank 2 switch sets the address of the device that
Bank 2 outputs 1 to 8 will mimic.
The table below shows the output module addressing:
Address
DIL 1
DIL 2
DIL 3
DIL 4
1
On
or off
Off
Off
Off
2
4
3
1
2 Off
On
Off Off
2
4
3
1
Output Module Numbering
The table below shows the output allocation when the
output modules are installed:
Address
Outputs
1
Expander 1, 1 - 8
2
Expander 2, 1 - 8
Outputs
The output module has 16 programmable outputs, which
can be used to drive auxiliary devices such as LED’s,
sounders or relays etc. Wire as per Panel Outputs shown on
page 24 (see page 53 for programming details). The
electrical characteristics for the outputs are shown below:
Bank
Outputs
Max Current
Type
1
1 to 8
100mA
Switched -ve
2
1 to 8
100mA
Switched -ve
Tamper Output
The tamper switch on the output module is connected to the
tamper output at the top of the module. If monitoring of the
lid tamper is required, this output must be connected to a
suitable input on the control panel or zone expander.