Installation
Premier 24
Installation Manual
24
INS248
Panel Outputs 1 - 8 and PG1
The control panel has 8 programmable outputs, which can be
used to drive auxiliary devices such as LED’s, sounders or
relays etc. (see page 55 for programming details). The table
below shows the electrical characteristics for each output:
Terminal
Max Current
Operation
1 100mA
Switched
0V
2 100mA
Switched
0V
3 100mA
Switched
0V
4 100mA
Switched
0V
5 100mA
Switched
0V
6 100mA
Switched
0V
7 100mA
Switched
0V
8 100mA
Switched
0V
PG1 100mA
Switched
0V
L/M
N/A
0V removed = Line Fault
R/R
N/A
0V applied to reset
DC+ N/A +12V
Power
(unfused)
DC- N/A
0V
Power
Wiring Outputs
The diagram below shows some typical wiring examples:
!
For details on testing outputs, see page 79.
Wiring a Stand Alone Communicator
The panel outputs can be used to trigger a stand alone
digital communicator.
The deffualt outputs are shown in the following table, see
page 55 for details of how to program outputs.
Panel Output
Function
1 Fire
Alarm
2 PA
Alarm
3 Intruder
Alarm
4 Armed
5 Zones
Locked
Out
6 Fault
Present
7 Confirmed
Alarm
8 Abort
The diagram below shows a typical wiring example:
DC +
Control Panel
Power
1 2 3 4 5 6 7 8
12V 0V
Stand Alone
Communicator
NO
NC
C
L/M
R/R
DC -
Channel Inputs
Programmed
as Positive
Removed
Line
Fault
Panel Outputs
1
2
3
4
5
6
7
8
Digi
Power
!
For details on testing the outputs, see page 79.