7.2
Fans
The system has one fan cage in front of the Flash sticks. These fans cool components in the
system. Internal sensors report the fans’ speeds.
If a fan degrades in performance, the front panel display will show the fan’s speed. In this
situation, the fan is still working, but it is not efficient. The error line ”
** SystemEnv Fan
8 speed is below normal levels (6122.82 RPM)
” scrolls across the top display row.
If a fan completely stops working an error is reported on the front panel display. The error
line ”
** SystemEnv Fan 8 speed is critically low (0.00 RPM)
” scrolls across the top
display row.
Warning:
Fix or replace failed fans as soon as possible. If too many fans fail the system temperatures
may rise past an acceptable range. If this happens, the system may turn off to prevent
component damage.
RamSan-810 User’s Manual
- 59 -
Texas Memory Systems, Inc.