SLOS787H – MAY 2012 – REVISED APRIL 2014
Figure 6-32. RX Sequence on I/O_6 in DM0 (Analog Capture)
Step 7: Terminating Direct Mode 0
After the EOF is received, data transmission is over, and Direct Mode 0 can be terminated by sending a
Stop Condition (in the case of SPI, make the Slave Select go high). The TRF7964A is returned to default
state.
6.11 Special Direct Mode for Improved MIFARE™ Compatibility
See the application report
TRF7964A Firmware Design Hints
).
6.12 Direct Commands from MCU to Reader
6.12.1 Command Codes
Table 6-14. Address and Command Word Bit Distribution
Command Code
Command
Comments
0x00
Idle
0x03
Software Initialization
Same as Power on Reset
0x0F
Reset
0x10
Transmission without CRC
0x11
Transmission with CRC
0x12
Delayed Transmission without CRC
0x13
Delayed Transmission with CRC
0x14
End of Frame/Transmit Next Time Slot
ISO15693
0x16
Block Receiver
0x17
Enable Receiver
0x18
Test internal RF (RSSI at RX input with TX off)
0x19
Test external RF (RSSI at RX input with TX on)
0x1A
Receiver Gain Adjust
46
Detailed Description
Copyright © 2012–2014, Texas Instruments Incorporated
Product Folder Links: