SLOS787H – MAY 2012 – REVISED APRIL 2014
Figure 6-25. Continuous Read of FIFO After Inventory Command
At this point, it is good form to reset the FIFO and then read out the RSSI value of the tag. In this case the
transponder is very close to the antenna, so value of 0x7F is recovered.
Figure 6-26. Reset FIFO and Read RSSI
40
Detailed Description
Copyright © 2012–2014, Texas Instruments Incorporated
Product Folder Links: