![Texas Instruments TMS320C2810 Data Manual Download Page 108](http://html.mh-extra.com/html/texas-instruments/tms320c2810/tms320c2810_data-manual_1097112108.webp)
WAKE INT
(B)
XCLKOUT
(A)
A0-A15
t
d(WAKE-IDLE)
t
w(WAKE-INT)
TMS320F2810, TMS320F2811, TMS320F2812
TMS320C2810, TMS320C2811, TMS320C2812
SPRS174T – APRIL 2001 – REVISED MAY 2012
www.ti.com
6.16 Low-Power Mode Wakeup Timing
Table 6-12. IDLE Mode Timing Requirements
MIN
NOM
MAX
UNIT
Without input qualifier
2t
c(SCO)
t
w(WAKE-INT)
Pulse duration, external wake-up signal
cycles
With input qualifier
1t
c(SCO)
+ IQT
(1)
(1)
Input Qualification Time (IQT) = [t
c(SCO)
× 2 × QUALPRD] × 5 + [t
c(SCO)
× 2 × QUALPRD].
Table 6-13. IDLE Mode Switching Characteristics
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
Delay time, external wake signal to program execution resume
(1)
Without input qualifier
8t
c(SCO)
•
Wake-up from Flash
cycles
–
Flash module in active state
With input qualifier
8t
c(SCO)
+ IQT
(2)
t
d(WAKE-IDLE)
Without input qualifier
1050t
c(SCO)
•
Wake-up from Flash
cycles
–
Flash module in sleep state
With input qualifier
1050t
c(SCO)
+ IQT
(2)
Without input qualifier
8t
c(SCO)
•
Wake-up from SARAM
cycles
With input qualifier
8t
c(SCO)
+ IQT
(2)
(1)
This is the time taken to begin execution of the instruction that immediately follows the IDLE instruction. Execution of an ISR (triggered
by the wake-up) signal involves additional latency.
(2)
Input Qualification Time (IQT) = [t
c(SCO)
× 2 × QUALPRD] × 5 + [t
c(SCO)
× 2 × QUALPRD].
A.
XCLKOUT = SYSCLKOUT
B.
WAKE INT can be any enabled interrupt, WDINT, XNMI, or XRS.
Figure 6-15. IDLE Entry and Exit Timing
108
Electrical Specifications
Copyright © 2001–2012, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Link(s):
TMS320F2810 TMS320F2811 TMS320F2812 TMS320C2810 TMS320C2811 TMS320C2812