TMS320F2810, TMS320F2811, TMS320F2812
TMS320C2810, TMS320C2811, TMS320C2812
SPRS174T – APRIL 2001 – REVISED MAY 2012
www.ti.com
6.13 Device Clock Table
This section provides the timing requirements and switching characteristics for the various clock options
available on the F281x and C281x DSPs.
Table 6-5
lists the cycle times of various clocks.
Table 6-5. TMS320F281x and TMS320C281x Clock Table and Nomenclature
MIN
NOM
MAX
UNIT
t
c(OSC)
, Cycle time
28.6
50
ns
On chip oscillator clock
Frequency
20
35
MHz
t
c(CI)
, Cycle time
6.67
250
ns
XCLKIN
Frequency
4
150
MHz
t
c(SCO)
, Cycle time
6.67
500
ns
SYSCLKOUT
Frequency
2
150
MHz
t
c(XCO)
, Cycle time
6.67
2000
ns
XCLKOUT
Frequency
0.5
150
MHz
t
c(HCO)
, Cycle time
6.67
13.3
(1)
ns
HSPCLK
Frequency
75
(1)
150
MHz
t
c(LCO)
, Cycle time
13.3
26.6
(1)
ns
LSPCLK
Frequency
37.5
(1)
75
MHz
t
c(ADCCLK)
, Cycle time
(2)
40
ns
ADC clock
Frequency
25
MHz
t
c(SPC)
, Cycle time
50
ns
SPI clock
Frequency
20
MHz
t
c(CKG)
, Cycle time
50
ns
McBSP
Frequency
20
MHz
t
c(XTIM)
, Cycle time
6.67
ns
XTIMCLK
Frequency
150
MHz
(1)
This is the default reset value if SYSCLKOUT = 150 MHz.
(2)
The maximum value for ADCCLK frequency is 25 MHz. For SYSCLKOUT values of 25 MHz or lower, ADCCLK has to be
SYSCLKOUT/2 or lower. ADCCLK = SYSCLKOUT is not a valid mode for any value of SYSCLKOUT.
102
Electrical Specifications
Copyright © 2001–2012, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Link(s):