SWRS046H – NOVEMBER 2006 – REVISED MARCH 2015
Table 5-49. GAIN_COMP Register (1Fh)
DEFAULT
REGISTER
NAME
ACTIVE
DESCRIPTION
VALUE
GAIN_COMP[7:0]
GAIN_COMP[7:0]
0
—
Signed compensation value for mixer I/Q gain error. Used for image
rejection calibration.
–128: approx. –1.16 dB adjustment between I and Q gain
–1: approx. –0.004 dB adjustment between I and Q gain
0: approx. +0.004 dB adjustment between I and Q gain
127: approx. +1.16 dB adjustment between I and Q gain
Table 5-50. POWERDOWN Register (20h)
DEFAULT
REGISTER
NAME
ACTIVE
DESCRIPTION
VALUE
POWERDOWN[7]
PA_PD
0
H
Sets PA in power down when PD_MODE[1:0]=2
POWERDOWN[6]
VCO_PD
0
H
Sets VCO in power down when PD_MODE[1:0]=2
POWERDOWN[5]
BUFF_PD
0
H
Sets VCO divider, LO buffers and prescaler in power-down when
PD_MODE[1:0]=2
POWERDOWN[4]
CHP_PD
0
H
Sets charge pump in power down when PD_MODE[1:0]=2
POWERDOWN[3]
LNAMIX_PD
0
H
Sets LNA/mixer in power down when PD_MODE[1:0]=2
POWERDOWN[2]
VGA_PD
0
H
Sets VGA in power down when PD_MODE[1:0]=2
POWERDOWN[1]
FILTER_PD
0
H
Sets image filter in power down when PD_MODE[1:0]=2
POWERDOWN[0]
ADC_PD
0
H
Sets ADC in power down when PD_MODE[1:0]=2
Table 5-51. TEST1 Register (21h, for Test Only)
DEFAULT
REGISTER
NAME
ACTIVE
DESCRIPTION
VALUE
TEST1[7:4]
CAL_DAC_OPEN[3:0]
4
—
Calibration DAC override value, active when BREAK_LOOP=1
TEST1[3:0]
CHP_CO[3:0]
13
—
Charge pump current override value
Table 5-52. TEST2 Register (22h, for Test Only)
DEFAULT
REGISTER
NAME
ACTIVE
DESCRIPTION
VALUE
TEST2[7]
BREAK_LOOP
0
H
0: PLL loop closed
1: PLL loop open
TEST2[6]
CHP_OVERRIDE
0
H
0: use calibrated value
1: use CHP_CO[3:0] value
TEST2[5]
VCO_OVERRIDE
0
H
0: use calibrated value
1: use VCO_AO[4:0] value
TEST2[4:0]
VCO_AO[4:0]
16
—
VCO_ARRAY override value
Table 5-53. TEST3 Register (23h, for Test Only)
DEFAULT
REGISTER
NAME
ACTIVE
DESCRIPTION
VALUE
TEST3[7]
VCO_CAL_MANUAL
0
H
Enables “manual” VCO calibration (test only)
TEST3[6]
VCO_CAL_OVERRIDE
0
H
Override VCO current calibration
0: Use calibrated value
1: Use VCO_CO[5:0] value
VCO_CAL_OVERRIDE controls VCO_CAL_CLK
if VCO_CAL_MANUAL=1. Negative transitions are then used to
sample VCO_CAL_COMP.
TEST3[5:0]
VCO_CO[5:0]
6
—
VCO_CAL_CURRENT override value
78
Detailed Description
Copyright © 2006–2015, Texas Instruments Incorporated
Product Folder Links: