SWRS046H – NOVEMBER 2006 – REVISED MARCH 2015
The frequency is swept from 300 MHz to 2800 MHz. Values are listed in
.
Figure 5-25. Typical optimum PA load impedance, 868/915 MHz
Table 5-10. Impedances at the First Three Harmonics
(868/915 MHz Matching Network)
FREQUENCY
REAL
IMAGINARY
(MHz)
(Ohms)
(Ohms)
868
15
24
915
20
35
1736
1.5
18
1830
1.7
22
2604
3.2
44
2745
3.6
45
5.12 Frequency Synthesizer
5.12.1 VCO, Charge Pump and PLL Loop Filter
The VCO is completely integrated and operates in the 1608 to 1920 MHz range. A frequency divider is
used to get a frequency in the UHF range (402 to 470 and 804 to 960 MHz). The BANDSELECT bit in the
ANALOG register selects the frequency band.
Copyright © 2006–2015, Texas Instruments Incorporated
Detailed Description
45