Power Down mode
Power Off
RESET_N=1
R
es
et
C
C
1
0
2
0
W
a
k
eupCC
1020
T
o
R
x
/
W
a
k
eupCC
1020
T
o
T
x
Calibrate VCO and PLL
S
etupC
C1020PD
Program all necessary registers
except MAIN and RESET
Turn on crystal oscillator, bias
generator and synthesizer
successively
Turn on power
Reset CC1020
MAIN: RX_TX=0, F_REG=0,
PD_MODE=1, FS_PD=1,
XOSC_PD=1, BIAS_PD=1
RESET_N=0
MAIN: PD_MODE=1, FS_PD=1,
XOSC_PD=1, BIAS_PD=1
PA_POWER=00h
Power Down mode
Power Off
Power Off
RESET_N=1
R
es
et
C
C
1
0
2
0
W
a
k
eupCC
1020
T
o
R
x
/
W
a
k
eupCC
1020
T
o
T
x
Calibrate VCO and PLL
S
etupC
C1020PD
Program all necessary registers
except MAIN and RESET
Turn on crystal oscillator, bias
generator and synthesizer
successively
Turn on power
Reset CC1020
MAIN: RX_TX=0, F_REG=0,
PD_MODE=1, FS_PD=1,
XOSC_PD=1, BIAS_PD=1
RESET_N=0
MAIN: PD_MODE=1, FS_PD=1,
XOSC_PD=1, BIAS_PD=1
PA_POWER=00h
SWRS046H – NOVEMBER 2006 – REVISED MARCH 2015
From power-down mode to TX:
1. WakeUpCC1020ToTX
2. SetupCC1020TX
Switching from RX to TX mode:
1. SetupCC1020TX
Switching from TX to RX mode:
1. SetupCC1020RX
Figure 5-27. Initializing Sequence