SWRS046H – NOVEMBER 2006 – REVISED MARCH 2015
The frequency is swept from 300 MHz to 2500 MHz. Values are listed in .
Figure 5-24. Typical Optimum PA Load Impedance, 433 MHz
Table 5-9. Impedances at the First 5 Harmonics
(433 MHz Matching Network)
FREQUENCY
REAL
IMAGINARY
(MHz)
(Ohms)
(Ohms)
433
54
44
866
20
173
1299
288
–563
1732
14
–123
2165
5
–66
44
Detailed Description
Copyright © 2006–2015, Texas Instruments Incorporated
Product Folder Links: