The battery cabinet functions in temperatures from
-10°C to 50°C
and at a maximum humidity of
85%
. Rooms that do not provide
these conditions must be air-conditioned. The battery cabinet may
not be exposed to corrosive atmospheres
. If the battery cabinet
is to be used in coastal areas or on farms, appropriate structural modifications to the installation room must be made to ensure
hazard-free operation of the storage system.
The battery cabinet must
not be exposed to direct sunlight
. It should also not be placed in the direct vicinity of
heat sources, such as
an oven or a fireplace
.
In
areas prone to flooding
, the battery cabinet must always be installed in an elevated location where it cannot be reached by
flooding. The storage system should be installed in a
fire-proof room
that is free of fire loads and is sealed with a
class F30 fire door
.
5 Installation location
The individual components of the TS series can weigh up to 120 kg and therefore should not be transported by a single person. It is
recommended that the system is installed by at least two people. The assistance of a hand truck is helpful. No more than 5 battery
modules should be stored on top of one another.
WARNING!
Battery modules are heavy (36kg). Please ensure safe installation. Use suitable means of transport only!