![Terex TW85 Operating Instructions Manual Download Page 117](http://html1.mh-extra.com/html/terex/tw85/tw85_operating-instructions-manual_1088809117.webp)
Troubleshooting
8
TW85
111
Fault
Possible cause
Remedy
8.15 Uppercarriage slewing too far
1 Swing
brake
defective
Check
condition of brake, repair or replace if
necessary
2
Unacceptable wear in swing operation
Check or replace if necessary
8.16 Working cylinders not operating satisfactorily
1
Seals in cylinders worn
Re-seal cylinders
2
Secondary valves defective
Check secondary valves and replace completely
if necessary
8.17 No or insufficient interlock of plunger cylinder
1
Mechanical fault
Check valves and replace if necessary
2
Electrical malfunction
Check switches, cables, connections, and fuse
3
No pressure build-up
Check hydraulic supply
4
Spongy interlock
Bleed plunger cylinders
8.18 Faults in the overload warning device
1
No
optical
display
Overload warning sensor or display module
defective.
Call Service Agent
2
No acoustic warning
Overload warning sensor is not switched on.
Overload warning sensor or display module
defective.
Call Service Agent