![Terex TW85 Operating Instructions Manual Download Page 116](http://html1.mh-extra.com/html/terex/tw85/tw85_operating-instructions-manual_1088809116.webp)
8 Troubleshooting
110
TW85
Fault
Possible cause
Remedy
8.12 Excavator installation not working
1
Toggle switch for working hydraulics set
to “OFF”
Set to “ON”
2
Left-hand armrest control panel lifted or
switch defective
Check, repair or replace if necessary
3
Oil supply to hydraulic pump interrupted
Check lines
4
Hydraulic pump has failed
Have hydraulic pump checked by a specialist and
replace, if necessary
5
Main relief valves have failed
Check main relief valves and replace, if
necessary
6
Maintenance ladder folded in
Fold up maintenance ladder
7
Switch on the maintenance ladder
defective
Repair or replace if necessary
8.13 Decrease in machine's performance
1
Insufficient engine power
Check diesel engine
2
Hydraulic oil level too low
Top up hydraulic oil to the mark
3
Pump is sucking up air
Re-tighten hose connections. Replace O-ring or
seals
4
Insufficient operating pressure
Readjust main relief valves (pressure cut-off) or
replace if required
8.14 Machine working too slowly and hydraulic oil is becoming too hot
1
Main relief valves (pressure cut-off) set
too low or valves are damaged
Readjust main relief valves (pressure cut-off) or
replace if required
2
Impermissible degree of wear of hydraulic
pump
Replace hydraulic pump
3
Hydraulic oil level too low
Top up hydraulic oil to the mark
4
Incorrect hydraulic oil
Quality of hydraulic oil must conform to our
recommendation
5
Air in hydraulic system
Tighten connections with engine off and system
relieved of pressure
6
Oil cooler dirty or damaged
Clean, check and replace if necessary