SCRUBBING
5300T MM382 (10–94)
3Ć30
10. Reinstall the mount bracket onto the new
pump. Hand tighten the three pan head
screws. Make sure the pump is orientated
correctly.
11. Reinstall the pump and bracket to the
solution tank. Tighten the two M6 pan head
screws to 11 – 14 Nm (7 – 10 ft lb).
12. Re–connect the small hose to the inlet side
of the pump. This is the bottom fitting.
13. Re–connect the small hose to the outlet side
of the pump. This is the top fitting.
14. Re–connect the pump to the main harness.
See schematic in the ELECTRICAL section
of this manual.
15. Raise the scrub brush.
16. Fill the solution tank and check the power
wand pump for proper operation.