![Tennant 5300T Service Manual Download Page 58](http://html1.mh-extra.com/html/tennant/5300t/5300t_service-manual_1087049058.webp)
ELECTRICAL
4Ć4
5300T MM382 (10–94)
SPECIFIC GRAVITY
BATTERY
at 27
C (80
F)
CHARGE
1.265
100% Charged
1.223
75% Charged
1.185
50% Charged
1.148
25% Charged
1.110
Discharged
NOTE: If the readings are taken when the battery
electrolyte is any temperature other than 27
C
(80
F), the reading must be temperature
corrected. Add or subtract to the specific gravity
reading 0.004, 4 points, for each 6
C (10
F)
above or below 27
C (80
F).
TO CHARGE THE BATTERIES
1. Drive the machine to a flat, dry surface in a
well-ventilated area.
2. Turn the machine power off and set the
parking brake if your machine has this
option.
FOR SAFETY: Before Leaving Or Servicing
Machine; Stop On Level Surface, Turn Off
Machine.
3. Lift up the recovery tank to get access to the
batteries.
NOTE: The recovery tank must be empty.
4. Check the water level in all the battery cells.
If the level is low, add just enough distilled
water to cover the plates. DO NOT
OVERFILL. The batteries can overflow
during charging due to expansion.
NOTE: Make sure the battery caps are in place
while charging.
FOR SAFETY: When Maintaining or Servicing
Machine, Avoid Contact With Battery Acid.
04380
09511
00879
Summary of Contents for 5300T