![Tennant 5300T Service Manual Download Page 47](http://html1.mh-extra.com/html/tennant/5300t/5300t_service-manual_1087049047.webp)
SCRUBBING
5300T MM382 (10–94)
3Ć25
TO REPLACE WATER FLOW CONTROL
CABLE
1. Turn the machine power off and set the
parking brake if your machine has this
option.
FOR SAFETY: Before Leaving Or Servicing
Machine; Stop On Level Surface, Turn Off
Machine.
2. Loosen the slotted set screw on the control
knob and remove knob.
3. Using a 1/2 inch wrench remove lock nut on
cable.
4. Remove all four phillips head mounting
screws that hold the bracket to the tank
body. Remove the bracket.
5. Pull the water control cable out of its
installed position next to the console and lay
it on the floor.
NOTE: Document how the water cable is routed
before removing.
6. Block the left transport wheel off the floor
and remove the wheel, using a 13 mm
socket and ratchet.
NOTE: Drain both tanks first! Place the scrub
head in the down position.
7. Using a 13 mm open-end wrench, remove
the bolt that secures the valve bracket
to the main frame.
8. Orientate the water valve and cable into
position so that the set screw holding the
cable end to the shaft on the valve can be
loosened. Use a 5/64 inch or 2 mm allen
wrench.