9. Pull the cable out from between the solution
tank and frame.
NOTE: Document how the cable is routed before
removing.
10. Feed the new cable between the solution
tank and frame and reconnect it to the water
valve shaft. Make sure the set screw seats
in the hole on the valve shaft.
11. Reinstall the water valve bracket to the main
frame.
12. Reinstall the left wheel, remove blocks and
set machine on floor.
13. Reinstall the opposite end of the control
cable to the bracket and install the bracket
onto the solution tank.
14. With your fingers, twist the end of the water
control cable clockwise as far as possible.
Install the control knob on the cable shaft
with the indicator portion of the knob pointing
in the minimum flow position. Tighten down
the slotted set screw on the knob.
NOTE: Test the control cable for proper water
flow.