20
20
An SMS can include single parameter or multiple parameters. When multiple parameters are to be
configured separate them with spaces. You don’t need to include “set” after every parameter. Just type
the parameters you want to configure along with their corresponding values and end the message with
“set”. e.g:
ip 222.222.222.222 port 1234 apn web.gsm mode slave auth_123456789 set
* It is very important that you type the SMS in lowercase, if not SMS configuration will fail. Also
each sms should end with set (except get1,get2 and restart), if not, only the parameters before set
would be configured, anything after set will be discarded.
** If you make a mistake (in format of sms or values of parameters) while sending sms, you will
receive a sms which would include errors.
***restart command will only be executed if there were no errors during configuration through
sms. We recommend you to restart WirlessCom/G10 after you have finished the configuration
(mode and bearer would only be changed after restart).
7.8 SMS details
WirlessCom/G10 has been programmed to send SMS (if configured) to the user in case of following
conditions,
•
GPRS activation fails
•
GPRS Server setup fails
•
CSD call fails
•
CSD call was not answered
(To receive SMS for above conditions bearer_fail_report should be on. SMS will be sent to
auth_phone1 first, if not configured/or sms fails, next numbers will be tried)
•
SMS request by user for getting configuration information
•
Error during configuration through SMS
•
Invalid command format sent through SMS