70
Time to movement (ID=1609)
9.6.7
Time to stationary (ID=1608)
If ignition is ON and no movement, event will be generated when TMO reached. This
functionality is 1-enabled, 0-disabled (default).
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
255
-
Scenario Enable (ID=1607)
Time to movement (ID=1609)
U8
9.6.8
Time to movement (ID=1609)
If ignition is ON and no movement, event will be generated when TMO reached. This
functionality is 1
–
enabled, 0
–
disabled (default).
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
255
-
Time to stationary (ID=1608)
Scenario Enable (ID=1607)
U8
9.6.9
Jamming Detection (ID=1606)
Jamming detection sensitivity can be set to: 0
–
disabled, 1
–
low sensitivity, 2
–
normal
sensitivity (default), 3
–
high sensitivity.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
3
-
U8
9.6.10
Alarm (ID=1610)
Alarm can be set to generate low or high priority event: 0
–
disabled (default), 1
–
low
priority event, 2
–
high priority event.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
2
-
U8
9.6.11
Unplug Detection (ID=1611)
Unplug detection can be set to: 0
–
disabled (default), 1
–
simple, 2
–
advanced.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
2
-
U8
9.6.12
Crash Detection (ID=1612)
Crash detection can be set to generate low or high priority event on crash: 0
–
disabled
(default), 1
–
low priority event, 2
–
high priority event.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
2
-
Duration (ID=1613)
U8