72
(ID=1291)
Activation Timeout (ID=1292)
Duration(ID1296)
Acceleration (ID=1297)
Angle(ID=1298)
9.6.18
Towing Detection Duration (ID=1296)
Defines time period to check Acceleration, Angle values.
Minimum
value
Maximum
value
Recommende
d value
Goes with (depends on)
parameters
Value
type
0
2
-
Towig detection enable/disable
(ID=1291)
Activation Timeout (ID=1292)
Ignition check after event (ID=1295)
Acceleration (ID=1297)
Angle(ID=1298)
U8
9.6.19
Towing Detection Acceleration (ID=1297)
It is max allowed cornering acceleration which can be reached while ignition is off.
Minimum
value
Maximum
value
Recommende
d value
Goes with (depends on)
parameters
Value
type
0
2
-
Towig detection enable/disable
(ID=1291)
Activation Timeout (ID=1292)
Ignition check after event (ID=1295)
Duration(ID1296)
Angle(ID=1298)
U8
9.6.20
Towing Detection Angle (ID=1298)
It is max allowed cornering angle which can be reached while ignition is off.
Minimum
value
Maximum
value
Recommende
d value
Goes with (depends on)
parameters
Value
type
0
2
-
Towig detection enable/disable
(ID=1291)
Activation Timeout (ID=1292)
Ignition check after event (ID=1295)
Duration(ID1296)
Acceleration (ID=1297)
U8
9.6.21
Trip (ID=1280)
This parameter enables ability to detect START and STOP of the trip. Possible values are: 0
–
disabled (default), 1
–
standard, 2
–
private/business.