78
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
-2147483648 2147483647
0
I/O#1 property parameter (ID=1300)
I/O#1 logic operand (ID=1304)
I/O#1 averaging length (ID=1305)
S32
9.8.5
I/O#1 logic operand (ID=1304)
Parameter defines when event is sent: 0
–
on range exit; 1
–
on range entrance; 2
–
both;
3
–
monitoring; 4
–
hysteresis.
Minimal
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
4
3
I/O#1 averaging length (ID=1305)
S8
9.8.6
I/O#1 averaging length (ID=1305)
Parameter defines I/O property sample length to average. If no averaging needed default
value is 1.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
2592000
1
I/O#1 logic operand (ID=1304)
S32
Other I/O property elements can be configured in same logic. All I/O element parameters
are listed in the next table.