8.2 Troubleshooting – flowchart
In fault conditions the machine may malfunction, as specified below:
MACHINE DOES NOT OPERATE OR OPERATION IS INTERRUPTED
THE MAIN SWITCH IS IN THE ON POSITION (1), THE POWER
WARNING LIGHT DOES NOT SWITCH ON.
The plug is not inserted in the sock-
et correctly.
Insert it correctly.
YES
The socket is faulty.
Have it substituted by a qualified
technician.
NO
YES
No electric power in the network or
in the socket.
Check that the disconnecting switches,
all-pole (phase & neutral) isolating switch-
es and residual current operated circuit
breakers (cut-outs) on the electrical sys-
tem, upstream of the socket, are closed.
If not, before closing them, make sure that
no one is carrying out electrical repairs.
NO
YES
A fuse designed to protect the aux-
iliary electrical system has blown.
Identify and eliminate the cause of the
overload and substitute the blown fuse
with another having the same specifica
-
tions and level of protection.
Contact the technical assistance service.
YES
NO
NO
The power cable is damaged.
Cut off the electricity supply to the socket
by opening the disconnecting switch up-
stream of it, then disconnect the plug and
contact the Technical assistance services.
YES
DO NOT TOUCH DAMAGED ELECTRIC CA-
BLES BEFORE CUTTING OFF
THE ELECTRICITY SUPPLY!
Contact the technical assistance
service.