4.5 Electricity supply
WORK ON ELECTRICAL CONNECTIONS MUST ONLY BE CARRIED OUT BY QUALIFIED TECHNICAL
PERSONNEL.
The machine must be powered at the voltage shown on the data plate at the top of the rear panel. Connect the machine
only to a power supply using a suitable earth connection.
The machine is supplied with a power cable to which
a qualified technician
must connect a plug suitable for the technical
data (voltage, current) on the data plate.
Connect the machine to a power socket using a suitable earth connection.
THE ELECTRIC SYSTEM THAT WILL POWER THE MACHINE MUST BE DESIGNED IN ACCORDANCE
WITH THE REGULATIONS IN FORCE AND INSTALLED BY QUALIFIED, CERTIFIED TECHNICAL PER-
SONNEL.
THE SOCKET MUST BE CONTROLLED BY A RESIDUAL CURRENT OPERATED CIRCUIT BREAKER,
AND MUST HAVE AN EFFECTIVE EARTH CONNECTION.
THE MANUFACTURER DECLINES ALL RESPONSIBILITY FOR ANY DAMAGE CAUSED BY AN UN-
SUITABLE ELECTRICITY SUPPLY SYSTEM OR EARTHING.
THE USE OF EXTENSION LEADS WHICH HAVE A CROSS-SECTION DIFFERENT TO THAT OF THE
MACHINE POWER CABLE MAY RESULT IN THE FOLLOWING FAULTS:
1. SLOW MOTOR START WITH TRIPPING OF OVERLOAD SWITCHES
2. MOTOR OVERHEATING WITH A DROP IN POWER
3. FAILURE OF MACHINE SWITCH ON - SWITCH OFF DEVICE
THE MANUFACTURER RECOMMENDS INSTALLATION OF THREE-PHASE MAGNETO-THERMAL
SWITCHES WHICH ALLOW POWER TO BE CUT OFF TO ALL PHASES EVEN IN THE EVENT OF AN
OVERLOAD ON ONLY ONE OF THEM. OTHER TYPES OF MAGNETO-THERMAL SWITCHES OR FUSES
ONLY CUT THE PHASE WHICH WAS SUBJECT TO OVERLOADING. IF THE VOLTAGE WERE TO FAIL
IN ONE OF THE THREE PHASES, THE MACHINE WOULD NOT STOP OPERATING, BUT THE MOTORS
WOULD QUICKLY SUFFER IRREPARABLE DAMAGE.