30
5.3 Programming
DURING TESTING, THE MACHINE WAS PROGRAMMED WITH OPTIMAL TEMPERATURE PA-
RAMETER VALUES FOR THE OPERATING CYCLE.
DO NOT CHANGE PROGRAMMING UNLESS THIS IS STRICTLY NECESSARY.
IF PARAMETER VALUES DO NEED TO BE ALTERED, MAKE ANY NECESSARY MACHINE PRO-
GRAMMING CHANGES.
▪ Check that the power LED (1) is on and press the machine ON/OFF 0/1
button.
▪
The machine prepares for operation and the tank temperature is shown
on the digital display (2).
▪
To change the (factory set) pasteurising cycle, adjust the mixture heating
and cooling temperatures.
▪ Keep the “PROGRAMMING” (B) button pressed for a few seconds to ac
-
cess the programming functions and change the operating cycle.
The functions are divided into clearly separate categories and are identified by a
flashing code that is used in sequence on the machine digital display.
Code Function
P1
Pasteurising cycle temperature regulation (Heating temperature and Cooling temperature).
P2
Setting of an additional time at the end of the heating phase, for holding at the heating temperature.
P3
Setting of the type of stirring at the end of the pasteurising cycle, when the
compressor restarts for holding at the cooling temperature (4°C factory setting).
There are 2 options:
-
SLo
(slow stirring when compressor restarts)
-
FSt
(fast stirring when compressor restarts)
P4
Setting of the SLOW stirring operating time, for the preservation phase when the compressor is
inactive. There are 3 options:
-
oFF
-
Con
(continuous stirring)
-
Numeric option
, for setting the stirring time (expressed in minutes)
1
B
2
Summary of Contents for EVOPASTO 120