![Telme EVOPASTO 120 Operating And Maintenance Manual Download Page 43](http://html1.mh-extra.com/html/telme/evopasto-120/evopasto-120_operating-and-maintenance-manual_1084174043.webp)
43
B) Washing machine components:
Wash the above-mentioned components using the tube brush
(F) and a disposable cloth (G) in a suitable container, using a
detergent solution at 50°C, then rinse them in cold water.
c) Refitting the components:
After washing, re-fit the components on the machine as described below:
•
Re-fitting the cover
- Place the cover (2) over the machine tank and line up the
holes in the cover with the through hole in the block.
- Insert the fixing pin (1) to secure the cover to the machine.
- Check that the fixing pin is completely inserted in the holes in
the cover and the block.
Incorrect installation or contact failure of the magnet on the cover activates a machine alarm, preventing
it from starting.
•
Refitting the mixing impeller
- Insert the bushing (3A) into the mixing impeller (3) drive.
TO AVOID VIBRATIONS AND/OR DAMAGING
PARTS, THE MIXING IMPELLER DRIVE MUST BE
COMPLETE WITH ITS BUSHING BEFORE INSERT-
ING IT ON THE MOTOR SHAFT SUPPORT.
- Fit the mixing impeller (3) on the support in the middle of the
tank.
- Slowly rotate the mixing impeller drive until its pin (15) engages
in the slot (16) in the motor driven shaft.
•
Refitting the drip tray
- Fit the drip tray (4) to the supporting bracket (5).
2
1
1
4
5
G
F
3
15
16
3A
3A
3
Chapter 6
Washing
TELME S.p.A.
Via S. Pertini, 10 - 26845 Codogno (LO)
Tel.: +39 0377 466.650 - [email protected]
Summary of Contents for EVOPASTO 120
Page 2: ...2...