9.
Programming Button
For programming the pasteurising cycle parameters. Allows you
to display/edit parameters set in the machine. See the section on “Programming”.
10.
Spout washing button
Activates automatic washing of the dispensing spout. When
spout washing is active the light (10a) in the button is lit.
Consult sec. 5.6 “Washing the spout after each dispensing operation” in this manual.
5.2 Switching on and starting the machine
EVERY DAY, WHEN YOU SWITCH ON THE MACHINE, CHECK THAT THE SAFETY DEVICES ARE
OPERATING CORRECTLY AS DESCRIBED IN DETAIL IN SECTION 7.5 OF THIS MANUAL.
Connect the machine power cable to a socket and check that the power LED
(A) is lit. Press the ON/OFF 0/1 button to prepare the machine to operate
and subsequently the tank temperature is displayed on the digital display (2).
The operation set at the factory proceeds as follows:
1. Production with pasteurising cycle:
- Mixture heating phase (to +85°C)
- Mixture cooling phase (to +4°C)
2. Automatic end-of-pasteurising-cycle preservation of the mixture at 4°C
The pasteurising cycle includes heating the mixture to 85°C and cooling it to 4°C. The temperature values are factory set.
However, the operator can decide to programme the preservation phase according to different operating modes, as described
in sec. 5.3 “Programming”.
DURING THE PRODUCT HEATING PHASE DO NOT TOUCH THE PRODUCT, THE COVER AND
THE UPPER SURFACE OF THE MACHINE. THE HIGH TEMPERATURE REACHED (85°C) COULD
CAUSE SERIOUS BURNS TO THE OPERATOR.
WE RECOMMEND USING HEAT PROTECTION GLOVES AND CLOTHING.