![tell IP Bridge Pro User Manual Download Page 54](http://html1.mh-extra.com/html/tell/ip-bridge-pro/ip-bridge-pro_user-manual_1083884054.webp)
T. E. L. L. SOFTWARE
HUNGÁRIA KFT
54
11.1.3
Premier and Premier Elit alarm control panel
Installation settings:
Figure 62.
Connect a programming cable to the alarm control panel, then connect its serial port output with the module
(see Figure 62. above). Only RX, TX and GND wires will be used, please connect these to the module in the
order shown in Figure 62. above.
Software settings:
Open the module's web interface, set the data for the serial port operation in the
Remote Modules
menu as
shown below:
Figure 63.
Remote module:
Select the „Receive only” option from the dropdown list.
Connection type:
Select the „Continuous
IP connection” option from the dropdown list. By this setting, the
connection between the programming software and the alarm control panel will be continuous.
Network:
In case the module has a 3G extension panel, the communication channel for transmitting serial data
also can be selected here.